Atop-technology EH7510 User manual Bedienungsanleitung Seite 69

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 120
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 68
Atop Industrial Managed Ethernet Switch
EH7510
User Manual V 1.0
63
2.12.4 802.1.x
Fig. 2.52
802.1x settings and configurations shown in Fig. 2.52.
Table 2.38
Label
Description
Factory Default
Quiet Period
Waiting time between requests when the
authorization has failed.
Range from 10 to 65535 seconds.
60
Tx Period
Waiting time for the supplicant’s EAP response
packet before retransmitting another EAP request
packet.
Range from 10 to 65535 seconds.
15
Supplicant Timeout
Waiting time for the supplicant response to the
authentication server’s EAP packet.
Range from 10 to 300 seconds.
30
Server Timeout
Waiting time for the authentication server’s
response to the supplicant’s EAP packet.
Range from 10 to 300 seconds.
30
Maximum
Requests
Maximum number of times to retransmit the
authentication servers EAP request packet to the
supplicant before the authentication session times
out.
Range from 2 to 10 seconds.
2
Reauth Period
Time between periodic re-authentication of the
supplicant.
Range from 30 to 65535 seconds.
3600
Seitenansicht 68
1 2 ... 64 65 66 67 68 69 70 71 72 73 74 ... 119 120

Kommentare zu diesen Handbüchern

Keine Kommentare